Smart Lower Limb Prosthesis Monitoring System Using Mechatronic Sensors Integrated with a Smartphone Application

Authors

  • munawir lasiyono Universitas Bima Sakapenta

DOI:

https://doi.org/10.56882/jisem.v5i2.80

Keywords:

Smart Prosthesis, Mechatronic Sensor, Inertial Measurement Unit, Smart Prosthesis, Mechatronic Sensor, IMU, Pressure Sensor, Smartphone, Smartphone

Abstract

The development of mechatronics and Internet of Things (IoT) technologies provides opportunities to develop smart lower limb prostheses capable of monitoring user activities in real time. This study aims to develop a smart prosthesis monitoring system using mechatronic sensors integrated with a smartphone application. The system employs an Inertial Measurement Unit (IMU) sensor to detect prosthetic movement and a pressure sensor to measure changes in prosthetic loading. Sensor data are processed using an ESP32 microcontroller and transmitted to a smartphone via Bluetooth Low Energy (BLE). The test results show that the system detects steps with an average error of 3.09% and achieves a communication success rate of 96.8%, with an average delay of 74 ms at a distance of 5 meters. The application displays step count, pressure, movement angle, activity status, sensor graphs, and usage history. The system provides a foundation for continuous activity monitoring in smart lower limb prostheses

References

H. Prasanth, M. Caban, U. Keller, G. Courtine, A. Ijspeert, H. Vallery, and J. von Zitzewitz, “Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review,” Sensors, vol. 21, no. 8, p. 2727, Apr. 2021, doi: 10.3390/s21082727.

A. Gouda and J. Andrysek, “Rules-Based Real-Time Gait Event Detection Algorithm for Lower-Limb Prosthesis Users during Level-Ground and Ramp Walking,” Sensors, vol. 22, no. 22, p. 8888, Nov. 2022, doi: 10.3390/s22228888.

M. O. Hopkins, S. Turner, R. Vaidyanathan, and A. McGregor, “Mapping Lower-Limb Prosthesis Load Distributions Using a Low-Cost Pressure Measurement System,” Frontiers in Medical Technology, vol. 4, p. 908002, Jun. 2022, doi: 10.3389/fmedt.2022.908002.

J. C. Mertens et al., “A novel portable sensor to monitor bodily positions and activities in transtibial prosthesis users,” Clinical Biomechanics, vol. 99, p. 105741, Oct. 2022, doi: 10.1016/j.clinbiomech.2022.105741.

J. W. Kwak et al., “Wireless sensors for continuous, multimodal measurements at the skin interface with lower limb prostheses,” Science Translational Medicine, vol. 12, no. 574, p. eabc4327, Dec. 2020, doi: 10.1126/scitranslmed.abc4327.

R. Kurniasih, A. Mais, and Sugihartatik, “Pengembangan Desain Prostesis Menggunakan Katup Udara untuk Disabilitas Amputasi,” J-CEKI: Jurnal Cendekia Ilmiah, vol. 4, no. 3, 2025.

A. A. Dewati and K. Muslim, “Pengaruh Jenis Sendi Lutut Kaki Prostetik dan Postur Tubuh Statis terhadap Aktivitas Otot dan Rating of Perceived Discomfort (RPD) pada Pengguna Kaki Prostetik,” Journal of Research in Industrial Engineering and Management, vol. 2, no. 2, pp. 1–8, Nov. 2024.

F. N. N. Budiman and K. Muslim, “Pengaruh Jenis Kaki Prostetik dan Postur Tubuh Awal ketika Melakukan Aktivitas Pengangkatan Pemindahan Beban dalam Kondisi Berdiri Diam terhadap Aktivitas Otot pada Pengguna Kaki Prostetik,” Journal of Research in Industrial Engineering and Management, vol. 2, no. 2, pp. 9–19, Nov. 2024.

E. B. Sutawika, Indrawanto, F. Ferryanto, S. Mihradi, and A. I. Mahyuddin, “Redesign of a Biomechanical Energy Regeneration-based Robotic Ankle Prosthesis using Indonesian Gait Data,” Journal of Engineering and Technological Sciences, vol. 53, no. 4, 2021, doi: 10.5614/j.eng.technol.sci.2021.53.4.6.

F. Y. Prabowo, Suyitno, and V. Yudha, “Perancangan dan Pengujian Statik Prototipe Lower Limb Prosthetic,” Journal of Innovation Research and Knowledge, vol. 4, no. 12, May 2025, doi: 10.53625/jirk.v4i12.10186.

S.-L. Han, M.-L. Cai, and M.-C. Pan, “Inertial Measuring System to Evaluate Gait Parameters and Dynamic Alignments for Lower-Limb Amputation Subjects,” Sensors, vol. 24, no. 5, p. 1519, Feb. 2024, doi: 10.3390/s24051519.

N.-Y. Park, S.-H. Eom, and E.-H. Lee, “A Study on the Fabrication of Pressure Measurement Sensors and Intention Verification in a Personalized Socket of Intelligent Above-Knee Prostheses: A Guideline for Fabricating Flexible Sensors Using Velostat Film,” Applied Sciences, vol. 14, no. 2, p. 734, Jan. 2024, doi: 10.3390/app14020734.

M. Samala et al., “A dataset of optical camera and IMU sensor derived kinematics of thirty transtibial prosthesis wearers,” Scientific Data, vol. 11, Aug. 2024, doi: 10.1038/s41597-024-03677-3.

M.-I. Keri, A. W. Shehata, P. D. Marasco, J. S. Hebert, and A. H. Vette, “A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users,” Sensors, vol. 21, no. 5, p. 1844, Mar. 2021, doi: 10.3390/s21051844.

A. Domínguez-Ruiz et al., “Low limb prostheses and complex human prosthetic interaction: A systematic literature review,” Frontiers in Robotics and AI, vol. 10, p. 1032748, Feb. 2023, doi: 10.3389/frobt.2023.1032748.

T. Fiumalbi et al., “A Multimodal Sensory Apparatus for Robotic Prosthetic Feet Combining Optoelectronic Pressure Transducers and IMU,” Sensors, vol. 22, no. 5, p. 1731, Feb. 2022, doi: 10.3390/s22051731.

Y. S. Wicaksana, D. F. Fitriyana, S. Anis, and M. M. Ardhianto, “Desain dan Simulasi Elemen Hingga pada Soket Prostesis Transtibial Berbasis 3D Printing Selama Siklus Gaya Berjalan,” Jurnal Pendidikan dan Teknologi Indonesia, vol. 5, no. 7, pp. 1925–1939, 2025.

M. Fatati, D. Setyawan, and L. H. Fikria, “Perbedaan Kecepatan Berjalan pada Pengguna Transtibial Prosthesis Tipe SACH Foot dan Single Axis Foot,” Medical Journal of Nusantara, vol. 3, no. 1, Jan. 2024, doi: 10.55080/mjn.v3i1.595.

J. Rattanakoch et al., “Validity and Reliability of Inertial Measurement Unit (IMU)-Derived 3D Joint Kinematics in Persons Wearing Transtibial Prosthesis,” Sensors, vol. 23, no. 3, p. 1738, Feb. 2023, doi: 10.3390/s23031738.

S. K. Rigot et al., “Validation of Proprietary and Novel Step-counting Algorithms for Individuals Ambulating With a Lower Limb Prosthesis,” Archives of Physical Medicine and Rehabilitation, vol. 105, no. 3, pp. 546–557, Mar. 2024, doi: 10.1016/j.apmr.2023.10.008.

H. T. T. Vu, H.-L. Cao, D. Dong, T. Verstraten, J. Geeroms, and B. Vanderborght, “Comparison of machine learning and deep learning-based methods for locomotion mode recognition using a single inertial measurement unit,” Frontiers in Neurorobotics, vol. 16, p. 923164, Nov. 2022, doi: 10.3389/fnbot.2022.923164.

M. Khafidh et al., “Rancang Bangun Alat Uji Dorsifleksi Telapak Kaki Prostesis Berdasarkan Standar ISO 10328,” Jurnal Rekayasa Mesin, vol. 18, no. 3, pp. 463–470, Dec. 2023, doi: 10.32497/jrm.v18i3.5127.

X. Bai, J. Yuan, M. Liu, H. Huang, and J. Feng, “Human factors considerations of interaction between wearers and intelligent lower-limb prostheses: a prospective discussion,” Journal of NeuroEngineering and Rehabilitation, vol. 21, p. 187, Oct. 2024, doi: 10.1186/s12984-024-01475-x.

N. Olaya-Mira, L. M. Gómez-Hernández, C. Viloria-Barragán, and I. C. Soto-Cardona, “Methods to assess lower limb prosthetic adaptation: a systematic review,” Journal of NeuroEngineering and Rehabilitation, vol. 22, p. 100, Apr. 2025, doi: 10.1186/s12984-024-01530-7.

C. F. Pană, L. F. Manta, I. C. Vladu, Ș. I. Cismaru, F. L. Petcu, D. Cojocaru, and N. Bîzdoacă, “The Design of a Smart Lower-Limb Prosthesis Supporting People with Transtibial Amputation—A Data Acquisition System,” Applied Sciences, vol. 12, no. 13, p. 6722, Jul. 2022, doi: 10.3390/app12136722.

Downloads

Published

2026-11-16

How to Cite

[1]
munawir lasiyono, “Smart Lower Limb Prosthesis Monitoring System Using Mechatronic Sensors Integrated with a Smartphone Application”, JISEM, vol. 5, no. 2, pp. 1–12, Nov. 2026.